This type of pipe has a second or third pipe running along the outside as shielding from the amount of heat that can pass through it.
Double wall stove pipe installation instructions.
There are two general types of double wall flue pipes.
Double wall black pipe dwb has been designed as the connector between the stove and a listed chimney system such as metal fab s model tg insulated all fuel chimney system.
Always read and follow installation instructions before installing your chimney system.
Reduce this maximum limit by 10 for every 90 bend or 5 for every 45 bend.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe.
Connect with us if you have any questions or comments for us.
I have a telescoping duravent stove pipe piece.
Because of the lip on the double wall pipe the crimped portion on the ceiling kit doesn t really fit snuggly inside the double wall stove pipe.
The maximum recommended length of double wall stove pipe should not exceed 20ft.
Provide sufficient slope in the horizontal run of the chimney connector 20mm per meter 1 4 per foot to enable any condensed liquid or creosote to run back toward the appliance.
The minimum installation clearances for certified double wall flue pipes are much less than those for single wall pipes.
You will want to start by running a pipe from the stove to.
Double wall black pipe dwb has been designed to connect a gas liquid or solid fuel fired residential type appliances and building heating appliance to a factory built listed chimney system such a metal fab s model tg all fuel chimney.
The double wall black pipe has been tested by warnock hersey to underwriters laboratories standard 103.
The associates at these stores will also be able to give you the advice you need regarding local regulations.
The dwb has an advantage over single wall black.
Run from stove to wall.
Have enough pipe so it extends higher than any other pipe or vent in the roof.
Determine the inner diameter of your chimney.
In the bottom picture is the stovepipe installed properly on the stove or do i need some kind of adapter.
Insert the black nail the wall thimble s black section to the section of the wall thimble into the opening studs with four 1 inch roofing nails.
To receive emails or mailers with product or company news and updates please fill out our customer form we look forward to hearing from you.
Installation and maintenance instructions for double wall black pipe 1 general.
You can find these at most stores that specialize in fireplaces.
Purchase double wall or triple wall pipe for a wood stove.
Download our chimney pipe installation guide or build your chimney pipe using our automated chimney pipe builder.
Follow local building codes and have your chimney inspected.
If the wall in the wall from inside the room and align thimble is going through a concrete wall and the nail holes with the studs.